PRODUCTS AT A GLANCE

T: 01788 577 399
F: 01788 577 899
sales@switchgear-systems.com
 

 


 
  Proline Sheet Steel Enclosed Products
 

 

Proline products are designed to offer quality, user friendly, practical and cost effective solutions for most indoor applications.

SP&N Switchfuses upto 100A open and new 3rd amendment
TP&N Switchfuses upto 125A
TP&N 16kA MCCB upto 160A
TP&N Load Break Isolators upto 160A

Features including:

  • Fully load rated AC22A 415V.
  • BSEN60947-3 Conformity.
  • Door interlocked padlockable handles on hinged units.
  • Alternative pole configurations and auxiliary contacts available
  • Removable gland plate top & bottom (not on SPN model)
Proline Products  
  Listed in Luckins Database
  Catalogue Page Technical Data
 
 
 
  Sheet Steel Enclosed Double Break Switchfuses TP&N and 4 pole up to 800A  
 

Features including:

  • Fully load rated AC23A 415 to 690V.
  • Fitted with general purpose BS88 HRS fuses.
  • Double break, fuses isolated on both sides.
  • BSEN60947-3 Conformity.
  • Door interlocked padlockable handles
  • Removable gland plate top (up to 700h) and bottom
Double Break Switchfuses  
  Listed in Luckins Database
  Catalogue Page Technical Data
 
 
 
  Sheet Steel Enclosed Load Break Isolator TP&N and 4 pole up to 1250A  
 

Features including:

  • Fully load rated AC23A 415 to 690V.
  • BSEN60947-3 Conformity.
  • Door interlocked padlockable handles.
  • Removable gland plate top (up to 700h) and bottom.
Load Break Isolator  
  Listed in Luckins  
  Catalogue Page Technical Data  
   
 
 
  Firemans Switch  
 

Features including:

  • Die Cast Aluminium enclosure.
  • Operates with fireman hook or axe – down for OFF.
  • Two handed switch ON.
  • 2 pole 230v AC22A.
  • 2 x M25 gland entries top and bottom.
Firemans Switch  
  Listed in Luckins
  Catalogue Page Technical Data
 
 
 
  Sheet Steel Busbar Chambers 4 pole up to 800A  
 

Features including:

  • 4 fully rated poles up to 800A.
  • Twin copper bar design for convenient clamping.
  • Fully compliant with BSEN 60439-1.
  • All panels removable.

Busbar Accessories

  • Connection clamps.
  • Flexibar connection kits.
  • Busbar joining kits.
Busbar Chambers  
  Listed in Luckins
  Catalogue Page Technical Data
 
 
 
  Sheet Steel Enclosed 3 & 4 pole MCCBs up to 800A and 4 pole & RCBOs up to 630A  
 

Features indlucing:

  • Fully load rated breakers.
  • BSEN60947-2, IEC 60439-1 conformity.
  • Thermomagnetic release as standard.
  • Door interlocked padlockable handles

RCBO’s have bult in one piece toroidal transformer and earth leakage relay.

  • Variable tripping current 0.025 – 25A.
  • Adjustable time delay 0.02 – 5 sec.
  • Auto or manual trip reset.
MCCB's  
RCCB's
  Listed in Luckins
  Catalogue Page Technical Data
 
 
 
  Sheet Steel Enclosed 4 Pole Contactors up to 400A  
 

Features including:

  • 240V coil with fuse protection.
  • IEC 60947-4 rated.
  • IP2X shrouded terminals.
  • Contactor with start/stop circuit
  • Stop Start units have red twist to reset emergency stop and green start pushbuttons wired into a standard stop/start circuit. Additional terminals are provided for wiring in an E stop loop.
4 Pole Contactor  
  Listed in Luckins
  Catalogue Page Technical Data
 
 
 
  Sheet Steel Enclosed Changeover Switches I-0-II  
 

4 pole Changeover Switches up to 1250A

4 pole Changeover Switches with Apliance inlets up to 125A

Features including:

  • Fully load rated AC22A 415 to 690V.
  • BSEN60947-3 Conformity.
  • Break-before-make with centre OFF.
  • Complete changeover switching system in one unit, no bridging bars required
  • Door interlocked padlockable handle.
Changeover Switch  
  Listed in Luckins
  Catalogue Page Technical Data
 
 
 
  Sheet Steel Junction Boxes – Generator Hook Ups  
 

A flexible solution to large cable management.  They can be used as junction boxes, to terminate or extend cables or as generator hook up points for bringing in a temporary supply.

Features including:

  • Insulated rating 1000V.
  • Fully shrouded. (see catalogue)
  • Bolt connection for cable lugs
  • Padlockable hinged door enclosure
Junction Box - Generator Hook Ups  
  Listed in Luckins
  Catalogue Page Technical Data
 
 
 
  Main to Backup ATS Panels  
 

These models are suited to applications where both power supplies are always assumed to be available for where no further intervention is required to activate supplies.

SP&N units up to 100A
TP&N units up to 400A

  • Features of Standard panels
    • All phases are monitored to protect against total power loss, phase failure and voltage variations of the primary supply.
    • Adjustable over and under voltage trip delay.
    • Electrical and mechanical interlocks between supplies.
    • External LED supply healthy indicators with parallel terminals for customer remote indication.

  • Features of Advanced panels
    All the features of the standard model as well as the following:-
    • User definable switching delay on both trip and return in all fault conditions.
    • External LED supply in use indicators with parallel terminals for customer remote indication.
Junction Box - Generator Hook Ups   
Junction Box - Generator Hook Ups 
  Listed in Luckins
  Catalogue Page Technical Data
 
 
 
  Main to Generator ATS Panels  
 

These models utilise microprocessor interface to monitor the primary supply and provide a volt free contact to connect to the generator start circuit.  Please note – these panels require a constant DC supply to operate.  If this is not available on site one can be integrated into the panel.

SP&N units upto 100A
TP&N units up to 1250A

Features including:

  • Primary supply phases monitored for total power loss, phase failure and voltage variations.
  • Volt free contact provided for generator negative start signal.
  • Additional n/o contact terminals.
  • Electrical and mechanical interlocks between supplies.
  • Configurable graphic interface providing:
    • Automatic mode.
    • Manual generator ON load mode
    • Manual generator OFF load mode
    • Adjustable delays for mains fail and return
    • Adjustable voltage limits for mains fail and return.
    • Adjustable delays for generator warm up and cool down.
    • External LED indication of supply healthy and supply in use.
    • Front of panel set up.
Mains to Generator ATS Panel  
Control Panel
  Listed in Luckins
  Catalogue Page Technical Data
 
 
 
  Sheet Steel Enclosed ATS Bypass I-II  
 

Switchgear systems have developed a range of switches that help provide bypass of Life Safety ATS panels, in a minimum number of operations, for both single line and dual line.

Features:

  • For Life Safety ATS installations
  • Break Before Make Operation.
  • Full load rated AC23A 415-690V.
  • Door interlocking padlockable handle.
Mains to Generator ATS Panel   
Mains to Generator ATS Panel 
  Listed in Luckins
  Catalogue Page Technical Data
 
 
 
  Sheet Steel Enclosed Bypass Switches I-0-II  
 

4 pole Horizontal Bypass Switches up to 160A

Designed to easily facilitate all cables from one direction with linking on the other side.

4 pole Layered Bypass Switches up to 1600A

Designed to minimize panel width and keep each set of cables separated.  As standard they facilitate bypass cabling from one direction and equipment from the other.  However a variety of cable directions can be catered for.

Featuring:

  • Break-Before-Make with OFF.
  • Fully load rated AC22A 415 – 690V.
  • BSEN60947-3 conformity.
  • Door interlocking padlockable handle.
Mains to Generator ATS Panel   
Mains to Generator ATS Panel 
  Listed in Luckins
  Catalogue Page Technical Data
 
 
 
  Sheet Steel Enclosed UPS Bypass Switches I-II  
 

Our range of single handle operation UPS Make Before Break bypass switches are designed to minimize panel width and keep each set of cables separated. As standard they facilitate bypass cabling from one direction and the UPS from the other. However a variety of cable directions can be catered for.

Featuring:

  • Make Before Break two Position I-II
  • Single Handle Operation.
  • Full load rated AC22A 415-690V.
  • BSEN60947-3 conformity.
  • Door interlocking padlockable handle.
Mains to Generator ATS Panel    
  Listed in Luckins
  Catalogue Page Technical Data
 
 
 
  Panelboards and Section Boards  
 

Switchgear Systems call on a range of metalwork systems from across the industry to offer fast design and build of fully tested and approved distribution solutions to meet a wide range of customer requirements.

 
  • IEC 61439 compliant panels.
  • 400A to 3200A fully rated busbars.
  • Fault ratings up to 120kA 1 sec.
  • Separation up to form 4-6.

Available components:

  • MCCB, RCCBO and ACBs
    - Single, three and four pole
    - 16A to 3200A - 16kA - 120kA.
    - Fixed or withdrawable.
    - Thermomagnetic or electronic trips.
    - Toggle or rotary handle operation.
Power Rated Earth and Neutral Bars
 
  • Switchfuse and Isolators.
  • Automatic and manual Changeover and Bypass switches.
  • Multifunction metering with pulsed or Modbus output.
  • Class I, II or III Surge protection.
Listed in Luckins
  Catalogue Page Technical Data
 
 
 
  Power Rated Earth and Neutral Bars  
 

Splitable and Non Splitable units up to 630A

Power rated earth and neutral bars are manufactured on sturdy 60mm din rail for mounting to the wall or inside distribution enclosures.  Alternative sizes are available to suit customer requirements.

Power Rated Earth and Neutral Bars  
  Listed in Luckins
  Catalogue Page Technical Data
 
 
 
  Combination and Distribution  
 
  • Specialist manufacturers of high quality combination units and distribution boards to your specification.
  • Approved supplier to the Cable TV and Telecoms Industries.
  • Units can include:
    • A full range of plug sockets and inlets.
    • Modular devices including RCD, MCB, RCBO.
    • Digital and card kWh metres.
    • Time control devices and other control gear.
  • All pre-wired to your specification.
Combination and Distribution  
  Listed in Luckins
  Catalogue Page Technical Data